Fronius Solar Inverter Fault Code

Error Code
Description

Troubleshooting

102
AC voltage too high

Submit a maintenance service request to your installer

103
AC voltage too low

Submit a maintenance service request to your installer

105
AC frequency too high

Submit a maintenance service request to your installer

106
AC frequency too low

Submit a maintenance service request to your installer

107
AC grid outside allowed limits

Submit a maintenance service request to your installer

108
Independent operation detected

Submit a maintenance service request to your installer

112
A resididual current monitoring unit (RCMU) error has occurred

Submit a maintenance service request to your installer

141
Grid frequency jump too high

Submit a maintenance service request to your installer

301
Excess AC Current

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

302
Excess DC Current

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

303
DC module overheating

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

304
AC module overheating

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

305
Power is not being fed in, although relay is closed

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

306
PV output is too low to feed

This fault will fix itself, if the fault keeps showing even when sufficient sunlight contact us. NOTE: These codes are shown at morning and night because of the low levels of sunlight at these times.

307
PV output is too low to feed

Shown morning and night because of the low levels of sunlight at these times. If persistent throughout day, submit a maintenance service request.

308
The intermediate circuit voltage is too high

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

309
DC input voltage MPPT 1 is too high

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

311
Polarity of the DC strings is reversed

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

313
DC input voltage MPPT 2 is too high

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

314
Current sensor calibration timeout

These faults generally fix themselves within a few hours. If the fault persists restart the system. If the error is still occurring, submit a maintenance service request.

315
AC current sensor error

Submit a maintenance service request to your installer

316
Interrupt check fail

Submit a maintenance service request to your installer

317
Unbalanced intermediate circuit voltage

Submit a maintenance service request to your installer

318
DC back current detected

Submit a maintenance service request to your installer

325
Connection area overheating

Submit a maintenance service request to your installer

326
Error with fan 1

Submit a maintenance service request to your installer

327
Error with fan 2

Submit a maintenance service request to your installer

401
AC Voltage too high

Submit a maintenance service request to your installer

406-407
Temperature sensor for AC module is faulty

Submit a maintenance service request to your installer

408
DC component measures in the grid too high

Submit a maintenance service request to your installer

412
Fixed voltage mode has selected instead of MPP voltage mode.Fixed voltage mode has been set at the wrong value.

Restart system. If code is ongoing submit a maintenance service request.

415
Safety cut out has triggered via option card or RECERBO

Restart system. If code is ongoing submit a maintenance service request.

416
Power stage set has no communication with control system

Restart system. If code is ongoing submit a maintenance service request.

417-419
Hardwire ID issue

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

420
Unable to communicate with Hybrid manager

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

421
HID range error

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

425
Unable to communicate with the power stage set

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

426-428
Hardwire fault

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

431
Software fault

Conduct an AC reset (Switch the AC circuit breaker off and on) ‘ then update the inverter firmware as above. If the fault code continues to appear submit a maintenance service request.

436
Functional incompatibility

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

437
Power stage fault

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

438
Functional incompatibility

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

443
The intermediate circuit voltage is too low or asymmetric

Generally will correct itself within a few hours. If not, restart the system.

445
Compatibility fault. Invalid power stage set configuration.

As per code 436

447
Insulation problem

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

448
The neutral conducted iOS not connected

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

450
The guard can’t be found

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

451
Memory fault detected

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

452
Communication problem between processors

Installer to attend site and disconnect / reconnect terminals and tighten screws.

453
Power stage set and grid voltage not compatible.

Customer restart system, then monitor over a few days. If the system is continually showing the fault for approx. 3 days request a maintenance service request.

454
Power stage set and grid frequency not compatible.

Customer restart system, then monitor over a few days. If the system is continually showing the fault for approx. 3 days request a maintenance service request.

456
Anto-islanding function is no longer implemented correctly

Customer restart system, then monitor over a few days. If the system is continually showing the fault for approx. 3 days request a maintenance service request.

457
The grid relay sticking or the nuetral conductor ground voltage is too high

Send installer to site to check grounding. Neutral conductor ground voltage has to be less than 30V. Submit a maintenance service request.

458-459
Issues when recording the measuring signal

Restart the system. Check there are no firmware updates. Leave for 24 hours if the fault still persists submit a maintenance service request.

460
Reference voltage source for the DSP is working out of tolerance

Restart the system. Check there are no firmware updates. Leave for 24 hours if the fault still persists submit a maintenance service request.

461
Error with DSP data memory

Restart the system. Check there are no firmware updates. Leave for 24 hours if the fault still persists submit a maintenance service request.

462
Fault with the DC feed monitoring routine

Restart the system. Check there are no firmware updates. Leave for 24 hours if the fault still persists submit a maintenance service request.

463
Reversed AC Polarity

The AC connector has been incorrectly inserted. This should not occur unless the customer has been fiddling with the system or they have had works done onsite and another technician has touched/changed the install. Submit a maintenance service request.

474
RCMU sensor is faulty

Submit a maintenance service request to your installer.

475
Insulation fault. The connection between the solar panel and ground is faulty

Submit a maintenance service request to your installer.

476
The driver supply voltage is too low

Restart system, if still present, submit a maintenance service request.

479
Immediate circuit relay has switched off

Restart system, if still present after an hour or two, submit a maintenance service request.

480-481
Inverter firmware need to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty. Submit a maintenance service request.

Restart system, if still present after an hour or two, submit a maintenance service request.

482
The setup phase after initial startup was interrupted

Full system restart required. Turn of AC circuit breaker, after 5 minutes turn back on, then after another 5-10 minutes restart the system. Complete during daylight hours.

483
The voltage UDC fixed on MPP2 string is out of limit

Send installer to site to check MPP settings. If correct and persisting, complete full restart including AC circuit breaker, if still persisting contact Fronius. Submit a maintenance request.

485
CAN transmit buffer is full

Conduct AC reset (turn off, wait 5 minutes and turn on again)

489
Permanent intermediate circuit capacitor over voltage

Submit a maintenance service request to your installer.

502
Insulation fault on the solar panels

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

509
No energy has been fed into the grid in the last 24 hours

Ensure no power outages in the area. If persistent for 2 days or more submit a maintenance service request.

515
Unable to communicate with filter

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

516
Unable to communicate with the storage unit

Generally will correct itself within a few hours. If not, restart the system. If code stays on for a prolonged period submit a maintenance service request.

517
No energy has been fed into the grid by MPPT 1 in the past 24 hours

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

518
Internal DSP fault

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

519
Unable to communicate with storage unit

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

520
No energy has been fed into the grid by MPPT 1 in the past 24 hours

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

522
DC is low in string 1

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

523
DC is low in string 2

Check nothing is blocking inverter air openings, if blocked, remove as these need to be clear. The fault should clear within 5 minutes but if not, restart the system. If the fault is still persistent, inverter may need to be replaced. Submit a maintenance service request.

528-529
There is a functional incompatibility (one or more of the PC boards are not compatible)

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

560
Grid frequency has become excessively high which is causing derating

Fault will fix itself, only requires attention if the fault occurs for a prolonged period of time.

564
See error 528-529

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

566
Arc Detector has been deactivated

Press enter (4th button from the left) wait 5 minutes and error should be clear.

567
The GVDPR is active and inverter will operate with reduced power output

System is still working but at slightly reduced power, code should clear itself within a few hours. If not submit a maintenance service request.

601
CAN bus is full

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

603
AC module sensor is faulty

Restart system, if still present submit a maintenance service request.

604
DC module sensor is faulty

Restart system, if still present submit a maintenance service request.

607
RCMU Fault

Press enter (4th button from the left) wait 5 minutes and error should be cleared.

608
See error 528-529

Inverter firmware needs to be updated. This needs to be done with enough daylight for whole update or the inverter will need to be replaced with likely no warranty.

609
Configuration value out of limits

Submit a maintenance service request to your installer.

701-730
Information about the internal processors status

Fault should clear itself within a few hours. If persistent, restart the system. If problem still not resolved submit a maintenance service request.

721
EEPROM has been reinstalled

Fault should clear itself within a few hours. If persistent, restart the system. If problem still not resolved submit a maintenance service request.

722-730
Information about the internal processors status

Fault should clear itself within a few hours. If persistent, restart the system. If problem still not resolved submit a maintenance service request.

731
USB flash drive not supported

Check the USB flash drive and files, may need to be replaced. Submit a maintenance service request.

732
Initialisation error with USB flash drive

Check the USB flash drive and files, may need to be replaced. Submit a maintenance service request.

733
USB flash drive not connected

Check the USB flash drive and files, may need to be replaced. Submit a maintenance service request.

734
Update file missing or not recognised

Check for updates to Firmware. Run update if required and fault should be cleared. If not, restart the system and if the error still occurs submit a maintenance service request.

735
Update file too old

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

736
Write or read error

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

737
Unable to open file

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

738
Unable to save log file

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

740
Error in file system

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

741
Error recording logging data

Contact Fronius to check USB drive and files, may need to be replaced. Have photos of code and inverter serial handy for call. Submit a maintenance service request.

743
Error during update
745
Update file corrupt
746
Error while updating
751
Time lost

Time and date on inverter needs to be reset. Submit a maintenance service request.

752
Communication error with real time clock module

Time and date on inverter needs to be reset. Submit a maintenance service request.

753
Real time clock module is in emergency mode

Time and date on inverter needs to be reset. Submit a maintenance service request.

754-755
Information about the processors status

Fronius needs to be contacted, generally they will want an installer onsite but can try without if the code is persistent.

757
Real time clock module hardware error

Fronius needs to be contacted, generally they will want an installer onsite but can try without if the code is persistent.

758
Real time clock module is in emergency mode

Time and date on on inverter needs to be reset. If code does not clear instantly restart the system.

760
Internal hardware fault
Submit a maintenance service request to your installer.
761-765&767
Information about internal processors status

Submit a maintenance service request to your installer.

766-773
Emergency power derating has triggered

Restart inverter, if problem persists submit a maintenance service request.

775
PMC power stage set unavailable

Press enter on the inverter (4th button from left). If problem still persists contact Fronius.

776
Device type invalid

Press enter on the inverter (4th button from left). If problem still persists contact Fronius.

779
CAN bus transmission error
781-794
Information about internal processors status

Battery Booster rebate for householders

FAQs

  • How does solar work?

    When the sun is shining, solar panels convert sunlight into DC (direct current) electricity. The solar inverter converts this electricity into AC (alternating current) power for use in your home. Your home appliances (fridge, dishwasher, pool pumps etc.) use this power instead of drawing power from the electricity grid.

    Any excess electricity generated by solar panels but not used by appliances is sent back (exported) to the electricity grid or used to charge a solar battery. Electricity Retailers pay a feed-in tariff for any electricity sent back to the grid.

    Solar generation, consumption and export is tracked and recorded through a smart meter, providing the data for electricity billing.

    Solar systems are most effective when they are well positioned (north-facing is optimal, but not essential) and exposed to enough sunlight without obstruction by shade caused from trees, power lines or other structures.

  • What size solar system is appropriate for my home?

    The appropriate size of a solar system for your home depends on various factors, including your household’s energy consumption, roof size, and the amount of sunlight your home receives. DE Energy Solar’s team can evaluate your energy usage and recommend a system size that is tailored to your specific needs.

  • What is the cost of installing a solar system with DE Energy Solar?

    The cost of installing a solar system with DE Energy Solar varies depending on the size and type of system, as well as other factors such as your location and electrical setup. Our team will provide you with a quote tailored to your specific needs and budget.

    Get a FREE Quote.

  • Do I qualify for solar rebate in QLD?

    If you are the homeowner.

    Any purchase of solar panel system will qualify for the rebate so long as the solar modules and solar inverter approval by the Clean Energy Council and; a CEC accredited installer performs the installation.

  • Does DE Energy Solar offer any government incentives or rebates?

    Yes, we can help you navigate government incentives and rebates that may be available for solar system installations. We will work with you to maximize your savings and ensure you take advantage of any available incentives.

  • What is Solar Feed-In Tariffs (FIT)?

    A feed-in tariff is the rate you are paid for any electricity generated by your rooftop solar system that is fed back into the grid.

    Feed-in tariffs are generally available for residential systems and do not necessarily extend to commercial customers. However, in most cases, commercial customers should be able to negotiate a rate with their electricity retailer.

    Almost all feed-in tariffs offered now are ‘net’ feed-in tariffs. This means that the electricity produced by your solar panels will be used in your home first, and you will only be paid for excess electricity that is exported to the grid.

    Feed-in tariffs differ from state to state and from retailer to retailer. In some states the government regulates a minimum rate, and in other states it is up to you to negotiate a deal with your electricity retailer.

    There is no government-regulated minimum retailer payment in New South Wales or southeast Queensland. It is worth shopping around to find out which electricity retailers offer the best rates for solar customers.

  • What if something goes wrong?

    If you have an issue with any solar product while it is under warranty, you should first contact your solar retailer to have the product replaced or repaired. If you are unable to contact your retailer, contact the manufacturer. Contact details should be provided on the warranty documentation.

    If you are not happy with the response you receive from your solar retailer, you can lodge a complaint with the relevant Fair Trading or Consumer Affairs in your state or territory. They can negotiate on your behalf and arrange mediation where necessary.

  • What should I do if the company I bought my solar system from has gone out of business?

    If your solar retailer has become insolvent and you are unable to contact the manufacturer, you can lodge a complaint with the solar retailer’s administrators. You can send out if a company has become insolvent via the Australian Securities and Investments Commission (ASIC) website or by phoning 1300 300 630.

    Your local Fair Trading or Consumer Affairs may also have information about the appointment of external administrators for insolvent companies. Likewise, if the manufacturer has
    gone into administration, you can lodge a complaint with the company’s administrators. As a consumer, you may become an unsecured creditor. If the external administrator fails to deal with your queries or complaints, you can also lodge a complaint with ASIC on 1300 300 630.

  • How much solar panels cost me and am I REALLY saving Money by going solar?

    COSTS

    The cost of installing a solar system can vary widely and is affected by a range of factors from where you live, the retailer or installer you choose, the warranties available, and the technology and size of your system.

    The major factors which will affect the price of a solar system are:

    1. Government rebates and incentives
    2. Contractor installation costs
    3. Type and number of panels
    4. Type and size of inverter
    5. Type of framing equipment and other system components
    6. Height and accessibility of roof and whether it is tiled or metal or concrete
    7. Any after sales service agreements

    Keeping the above variables in mind, these tables provide an approximate guide on the price range for solar systems in Australia’s major capital cities. Government rebates are included in these figures. Please note that the market costs change quickly so these numbers are illustrative only.

    Estimated prices for residential solar systems

    SYSTEM SIZE ESTIMATED PRICE RANGE
    (Out of Pocket)
    2 kW $2,800 – $5,600
    3 kW $2,900 – $6,950
    4 kW $3,400 – $7,900
    5 kW $3,500 – $9,500
    10 kW $7,600 – $14,100

     

    SAVINGS

    There are numerous factors that affect your suitability for solar and the period it will take for your system to pay for itself.

    The amount of money your household will save on power bills by going solar is affected by several factors, including:

    Your energy consumption and the size of your solar power system – if you use more power than your system can produce, your savings will be reduced. It’s important to choose the correct system for your needs.

    Your feed-in tariff – this is the amount your electricity retailer pays you for any excess power your solar panels generate.

    Your usage patterns – solar panels can only generate electricity while the sun is shining. This means that households that use a lot of power during the day may attract greater savings than those that consume most of their power at night. However, you will still receive a feed-in tariff for any excess electricity you generate during the day.

    Where you live – some areas of Australia receive a lot more sunlight than others, so a solar system in Brisbane will usually generate more power than one in Hobart.

  • How do I choose a solar retailer?

    When choosing a solar or storage retailer and/or installer, it pays to do a little research. The Clean Energy Council recommends choosing an Approved Solar Retailer who has signed on to the Solar Retailer Code of Conduct and only uses designers and installers who are accredited by the Clean Energy Council.

  • What is an Approved Solar Retailer?

    The Clean Energy Council Approved Solar Retailer program is a way for businesses that sell solar and storage to show their commitment to responsible sales and marketing activities and industry best practice.

    Authorised by the Australian Competition and Consumer Commission (ACCC), the program aims to lift the bar higher than the minimum requirements set by government and regulations, and bring about a better standard of service within the solar and storage industry.

    Approved Solar Retailers have committed to complying with the program’s Code of Conduct. If an Approved Solar Retailer fails to comply with the requirements of the Code, the Clean Energy Council may take action against them.

  • What is Clean Energy Council (CEC)?

    The Clean Energy Council is the peak body for the clean energy industry in Australia.

    We are a not-for-profit, membership-based organisation. We represent and work with Australia’s leading renewable energy and energy storage businesses, as well as rooftop solar installers, to further the development of clean energy in Australia.

  • How long does the installation process take with DE Energy Solar?

    The installation process with DE Energy Solar typically takes between one to three days, depending on the size and complexity of the system. Our team will work with you to schedule the installation at a time that is convenient for you.

  • What kind of maintenance is required for a solar system?

    A solar system installed by DE Energy Solar requires minimal maintenance, but it is important to keep the panels clean and free from debris to ensure optimal performance. Our team will provide you with maintenance tips and advice to keep your system running smoothly.

  • Can I sell excess energy back to the grid with a solar system?

    Yes, DE Energy Solar’s solar systems are designed to be grid-tied, which means you can sell any excess energy back to the grid through your utility provider’s net metering program.

  • Are there any restrictions on installing a solar system?

    There may be some restrictions on installing a solar system in certain areas, particularly if you live in a heritage-listed or protected area. Our team will help you navigate any relevant regulations and guidelines to ensure your installation complies with all necessary requirements.

  • How can I schedule a consultation with DE Energy Solar to discuss solar system installation?

    You can schedule a consultation with DE Energy Solar by calling our team at 1800 931 668 or by filling out the FREE quote form on our website. Our team will be happy to answer any questions you may have and provide you with a customized quote for your solar system installation.

  • How long does a solar system last?

    Solar panels typically come with a warranty of 25 years or more, and can last up to 30 years or longer with proper maintenance. Inverter systems typically have a shorter lifespan of 10-15 years, but can be easily replaced when necessary.

  • Will a solar system work during a power outage?

    In most cases, a solar system will not work during a power outage. However, DE Energy Solar can install battery backup systems that allow you to continue using your solar-generated energy during a blackout.

  • Can I finance the cost of a solar system installation with DE Energy Solar?

    Yes, DE Energy Solar offers financing options to help you spread out the cost of your solar system installation over time. Our team can work with you to find a financing plan that meets your needs and budget.

  • Will a solar system increase the value of my home?

    Studies have shown that homes with solar systems installed have a higher resale value than those without. Additionally, a solar system can help reduce your home’s energy bills, making it more attractive to potential buyers.

  • Do I need a north-facing roof to install a solar system?

    While a north-facing roof is generally considered to be the most optimal for solar panel installations in Australia, other orientations can still be effective. DE Energy Solar can evaluate your roof’s orientation and recommend the best solution for your specific location and energy needs.

  • Can I still use electricity from the grid with a solar system?

    Yes, a solar system is designed to work in conjunction with the grid. You will still have access to electricity from the grid when necessary, such as during periods of low sunlight or high energy demand.

  • How does DE Energy Solar ensure the quality of its solar systems and installations?

    DE Energy Solar sources its solar systems from reputable manufacturers (Tier 1 Solar Panels) and follows industry best practices for installation and quality assurance (CEC Approved Solar Retailer). Our team is committed to providing high-quality solar solutions that meet our customers’ needs and exceed their expectations.

DE Energy is a proud New Energy Tech Approved Seller committed to meeting consumer protection standards throughout your customer journey with us.
These standards have been designed by peak consumer and industry bodies to help raise consumer protection across the solar, battery storage and new energy tech industry.

As Approved Sellers, DE Energy is committed to:

  • Providing you with clear, accurate and relevant information to help you make informed choices
  • Encouraging you to be aware of your rights under the law and the New Energy Tech Consumer Code (NETCC)
  • Ensuring that our sales practices are responsible
  • Ensuring that products, systems, services and documentation provided under the NETCC are suitable and fit for purpose
  • Supporting staff training and work processes that ensure that we comply with the law and the NETCC
  • Ensuring that we will be responsive to your needs and taking prompt, appropriate action if you make a complaint.